Main |
|
Range |
TeSys TeSys Deca
|
Range of product |
TeSys D TeSys Deca
|
Product or component type |
Contactor |
Device short name |
LC1D |
Contactor application |
Resistive load
Motor control
|
Utilisation category |
AC-1
AC-4
AC-3
AC-3e
|
Poles description |
3P |
Motor power kW |
5.5 kW at 220...230 V AC 50/60 Hz (AC-3)
11 kW at 380...400 V AC 50/60 Hz (AC-3)
11 kW at 415...440 V AC 50/60 Hz (AC-3)
15 kW at 500 V AC 50/60 Hz (AC-3)
15 kW at 660...690 V AC 50/60 Hz (AC-3)
5.5 kW at 400 V AC 50/60 Hz (AC-4)
5.5 kW at 220...230 V AC 50/60 Hz (AC-3e)
11 kW at 380...400 V AC 50/60 Hz (AC-3e)
11 kW at 415...440 V AC 50/60 Hz (AC-3e)
15 kW at 500 V AC 50/60 Hz (AC-3e)
15kW at 660...690 V AC 50/60 Hz (AC-3e)
|
Motor power hp |
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 115 V AC 50/60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
15 hp at 460/480 V AC 50/60 Hz for 3 phases motors
20 hp at 575/600 V AC 50/60 Hz for 3 phases motors
7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
|
Pole contact composition |
3 NO |
Contact compatibility |
M2 |
Protective cover |
With |
Auxiliary contacts type |
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
|
Auxiliary contact composition |
1 NO + 1 NC |
[Ui] rated insulation voltage |
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
|
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947 |
Overvoltage category |
III |
[Ith] conventional free air thermal current |
10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit
|
Irms rated making capacity |
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
|
Rated breaking capacity |
450 A at 440 V for power circuit conforming to IEC 60947 |
Control circuit type |
AC at 50/60 Hz |
Coil technology |
Without built-in suppressor module |
Control circuit voltage limits |
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
|
Average impedance |
2 mOhm - Ith 40 A 50 Hz for power circuit |
Power dissipation per pole |
3.2 W AC-1 1.
25 W AC-3
1.25 W AC-3e
|
Minimum switching current |
5 mA for signalling circuit |
Minimum switching voltage |
17 V for signalling circuit |
Non-overlap time |
1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
|
Maximum operating rate |
3600 cyc/h 60 °C |
Inrush power in VA |
70 VA 60 Hz cos phi 0.75 (at 20 °C) 70 VA 50 Hz cos phi 0.75 (at 20 °C)
|
Hold-in power consumption in VA |
7.5 VA 60 Hz cos phi 0.3 (at 20 °C) 7 VA 50 Hz cos phi 0.3 (at 20 °C)
|
Insulation resistance |
> 10 MOhm for signalling c |
Tightening torque |
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Mounting support |
Plate Rail
|
Mechanical durability |
15 Mcycles |
Safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
|
Operating altitude |
0...3000 m |
Compatibility code |
LC1D |
Product certifications |
BV
GL
LROS (Lloyds register of shipping)
GOST
UL
DNV
CCC
CSA
RINA
UKCA |
>> What condition of the environment could Schneider ac Magnetic Contactor LC1D25M7 be used?
Environment |
|
Climatic withstand |
conforming to IACS E10 conforming to IEC 60947-1 Annex Q category D
|
Ambient air temperature for storage |
-60…80 °C |
Fire resistance |
850 °C conforming to IEC 60695-2-1 |
Mechanical robustness |
Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor open: 10 Gn for 11 ms
Shocks contactor closed: 15 Gn for 11 ms |
>> What is the dimension of Schneider AC Magnetic Contactor LC1D25M7?
Dimension |
|
Height |
85 mm |
Width |
45 mm |
Depth |
92 mm |
Net weight |
0.37 kg |
Related Products
>> Full types of Schneider ac magnetic contactors LC1D series in stock now:
LC1D38M7
LC1D40AM7
LC1D65AM7
FAQ
Q1: Do you have a catalogue? Can you send me the catalogue to have a check of all your product ?
Yes , We have product catalogs. Please inform your requested brand, model, then we will reply by on line or Email to sending the catalog.
Q2: I need your price list of all your products, do you have a price list ?
Please inform exactly brand, series or specification, then we will try to our best to provide price list of products. Because we have so many items, and need to focus your requested. If you don't have modes, we also can provide catalog for reference.
If you want to check any price of our products, please contact us.We will send offer to you soon!
Q3: What kind of payment do you accept ?
We accept T/T, Paypal, Western Union, Alibaba trade assurance and etc. Please contact us and our salesmen will reply your exactly payment way. Hope we can create a better business relationship with you.
Q4: I can’t assure the models of product from catalog, can you choose models for me?
We are the Schneider Distributor in Taiwan, you can get our service at quotation, technique consult, ,ex-stock products, after sales service and etc.
So you can provide specification let us check.
Q5: How to ship my order ? Is it safe?
For small package, we will send it by Express, such as DHL, FedEx, TNT, EMS, OCS. SF. That’s a Door to Door service.
For big packages, we will send them by Air or by sea.We will use good packing and ensure the goods safety.
For big packages, we will send them by Air or by sea.We will use good packing and ensure the goods safety.
Certifications
Packing & Delivery
Our Company
http://www.tw-rstpower.com/